The Linear AP-5 is a versatile wireless access controller designed for various applications, including door strikes, mag-locks, and gates. Its compact size and wireless design make it suitable for diverse access control requirements. The AP-5 operates on 12-24 volts AC/DC, features a high-gain superheterodyne receiver, and supports up to 500 feet of transmission range. It is ideal for controlling access points in both residential and commercial settings, offering reliable and efficient operation.

1.1 Overview of the Linear AP-5 Wireless Access Controller

The Linear AP-5 is a standalone, multi-purpose wireless access controller designed for a wide range of applications, including door strikes, mag-locks, gates, and automatic doors. Its compact, wireless design makes it highly adaptable for various access control needs. The AP-5 operates on 12-24 volts AC or DC, ensuring flexibility in power supply. It features a high-gain superheterodyne receiver for reliable signal reception and can store up to 480 MegaCode transmitters in its memory. This controller is ideal for both residential and commercial settings, offering a robust solution for managing access points efficiently. Its versatility and ease of installation make it a popular choice for access control systems.

1.2 Importance of the Manual for Installation and Operation

The manual is essential for the proper installation, configuration, and operation of the Linear AP-5 Wireless Access Controller. It provides detailed instructions to ensure safe and effective setup, including wiring guidelines and safety precautions. The manual also offers step-by-step programming instructions for adding MegaCode transmitters, setting user codes, and utilizing advanced features. Troubleshooting tips and maintenance recommendations are included to address common issues and extend the device’s lifespan. By following the manual, users can maximize the AP-5’s functionality, ensure reliable performance, and avoid potential hazards associated with improper installation or operation. Referencing the manual is crucial for achieving optimal results and maintaining system integrity.

Key Features of the Linear AP-5

The Linear AP-5 features a compact, wireless design with a high-gain superheterodyne receiver for reliable signal reception. It supports MegaCode transmitters and is compatible with door strikes, mag-locks, and gates, offering versatile access control solutions.

2.1 Wireless Design and Compact Size

The Linear AP-5 boasts a sleek, wireless design that simplifies installation and enhances flexibility in access control systems. Its compact size allows it to fit seamlessly into various environments, making it ideal for residential or commercial applications. The wireless functionality eliminates the need for cumbersome wiring, reducing installation time and potential points of failure. This design ensures the AP-5 can be easily mounted in tight spaces while maintaining reliable performance. Its portability and adaptability make it a versatile solution for controlling door strikes, mag-locks, gates, and other access points. The compact form factor complements its robust functionality, ensuring efficient operation without compromising space.

2.2 High-Gain Superheterodyne Receiver

The Linear AP-5 features a high-gain superheterodyne receiver, ensuring reliable signal reception and minimizing interference. This advanced technology enhances the device’s ability to capture weak signals, even in challenging environments. The receiver’s high sensitivity allows it to communicate with transmitters up to 500 feet away, providing consistent and dependable performance. Its robust design ensures clear communication, reducing the likelihood of signal dropouts or interference from external sources. This feature makes the AP-5 particularly suitable for large properties or applications where strong, stable wireless connectivity is essential. The high-gain receiver is a key factor in the AP-5’s reputation for reliability and performance in access control systems.

2.3 Compatibility with Door Strikes, Mag-Locks, and Gates

The Linear AP-5 is designed to seamlessly integrate with a variety of access control devices, including door strikes, mag-locks, and gates. Its compatibility ensures flexible installation across different security systems. The AP-5 can control up to two door strikes or mag-locks, making it ideal for securing multiple entry points. Additionally, it supports automated gates, providing a comprehensive solution for managing access in both residential and commercial settings. This versatility allows users to enhance security while maintaining ease of operation. The AP-5’s adaptability ensures it meets diverse application needs, offering a reliable and efficient access control solution for various environments.

Technical Specifications

The Linear AP-5 operates on 12-24 volts AC/DC, supports up to 1 Amp relay output, and offers a transmission range of up to 500 feet. It ensures reliable performance across various access control systems, making it a robust solution for diverse applications.

3.1 Power Requirements (12-24 Volts AC/DC)

The Linear AP-5 requires a power supply of 12-24 volts AC or DC, ensuring flexibility in installation. It can be powered directly from the radio power output of most gate operators or via a low-voltage plug-in transformer. The device is designed to operate efficiently within this voltage range, supporting reliable performance for access control systems. An earth ground terminal is provided to enhance safety and protect against lightning strikes. This power versatility makes the AP-5 suitable for various applications, from residential to commercial settings, ensuring consistent and dependable operation.

3.2 Relay Output Capacity (Up to 1 Amp)

The Linear AP-5 features a relay output capacity of up to 1 Amp, enabling it to control a variety of access control devices. This capacity is sufficient for operating door strikes, mag-locks, and gates, making it suitable for both residential and commercial applications. The relays can be activated automatically through wireless signals or manually via the keypad. Each relay can handle up to 1 Amp of current, ensuring reliable operation for connected devices; This feature enhances the AP-5’s versatility, allowing it to manage multiple access points efficiently while maintaining safety and performance standards.

3.3 Transmission Range (Up to 500 Feet)

The Linear AP-5 offers a robust transmission range of up to 500 feet, ensuring reliable communication between the controller and wireless transmitters or keypads. This extended range is particularly beneficial for large properties or installations where devices are spread out. The AP-5 utilizes MegaCode signals, which are encoded for security and reliability, minimizing interference from other wireless devices. The high-gain superheterodyne receiver further enhances signal strength, ensuring consistent performance even in challenging environments. This feature makes the AP-5 ideal for controlling access points such as gates, doors, and barriers in both residential and commercial settings, providing a seamless and efficient access control solution.

Installation Instructions

The Linear AP-5 installation process is straightforward, requiring a pre-installation checklist and step-by-step guidance. It operates on 12-24 volts AC/DC and can be powered directly from gate operators or a low-voltage transformer, ensuring easy setup for access control systems.

4.1 Pre-Installation Checklist

Before installing the Linear AP-5, ensure you have a power supply of 12-24 volts AC/DC and appropriate wiring. Verify compatibility with door strikes, mag-locks, or gates. Check the transmission range of up to 500 feet and ensure no physical obstructions. Gather necessary tools, such as a screwdriver and mounting hardware. Confirm the availability of a low-voltage plug-in transformer if not powered directly by the gate operator. Review the manual for specific installation steps and safety guidelines. Ensure all components, including the antenna and receiver, are included in the package. Familiarize yourself with the keypad functions for transmitter programming and relay activation. Prepare a safe and dry location for mounting the controller to ensure optimal performance and durability.

4.2 Step-by-Step Installation Process

Mount the Linear AP-5 controller in a secure, dry location. Connect the power supply (12-24V AC/DC) to the designated terminals. Wire the relays to the door strike, mag-lock, or gate operator according to the manual. Install the antenna to ensure optimal signal reception. Program transmitters or keypads by following the learn procedure in the manual. Test the system to ensure proper operation. For door or gate control, press the learn button and activate the transmitter. Verify relay activation and obstacle detection (if applicable). Refer to the manual for specific wiring diagrams and safety precautions to ensure a successful installation.

4.3 Mounting and Wiring Guidelines

Mount the AP-5 in a secure, dry location to protect it from environmental damage. Use the provided screws to attach the unit to a flat surface. Ensure the antenna is positioned for optimal signal strength, avoiding obstructions. Connect the power supply (12-24V AC/DC) to the designated terminals, ensuring proper polarity. Wire the relays to the door strike, mag-lock, or gate operator, following the wiring diagram in the manual. Use low-voltage wiring for connections to avoid interference. Ground the unit to prevent electrical noise and ensure safe operation. Double-check all connections before powering on the system to guarantee reliable performance and safety.

Programming the Linear AP-5

Program the AP-5 by adding MegaCode transmitters or setting user codes (2-6 digits). Use the keypad to learn transmitters or suspend them for secure access control.

5.1 Adding MegaCode Transmitters

To add MegaCode transmitters, press and hold the learn button until the LED blinks. Then, press the transmitter button to sync it with the AP-5. The controller can store up to 480 MegaCode transmitters, allowing for extensive access control. Each transmitter is block-coded for security. The AP-5 supports a transmission range of up to 500 feet, ensuring reliable communication. Additionally, it can program up to six MGT supervised safety edge transmitters for advanced functionality; This feature-rich system ensures seamless integration and secure access management.

5.2 Setting Up User Codes (2 to 6 Digits)

To set up user codes on the Linear AP-5, access the programming menu using the master code. Select the option to add a new user code, which can be 2 to 6 digits long. Enter the desired code and save it. The AP-5 allows multiple user codes to be stored, providing flexible access control. Ensure the master code is updated for enhanced security. Refer to the manual for detailed steps to add, modify, or delete user codes efficiently.

5.3 Advanced Programming Features

The Linear AP-5 offers advanced programming features to enhance access control functionality. It supports the storage of up to 480 MegaCode transmitters, enabling multiple users to be programmed efficiently. Additionally, the AP-5 can integrate with supervised safety edge transmitters, ensuring safe operation of gates or doors. Advanced features include relay activation for obstacle detection and the ability to program user codes directly via the keypad or compatible wireless keypads. These features provide flexibility and scalability for various access control applications. Refer to the manual for detailed instructions on configuring these advanced settings to meet specific installation requirements and ensure optimal performance.

Maintenance and Troubleshooting

Regular maintenance ensures optimal performance. Check power supply, antenna alignment, and connections. Troubleshoot common issues like transmitter range problems or relay malfunctions. Refer to the manual for reset procedures and solutions.

6.1 Regular Maintenance Tips

Regular maintenance is crucial to ensure the Linear AP-5 operates efficiently. Clean the unit periodically to prevent dust buildup. Check the antenna for proper alignment and damage. Verify all wiring connections are secure and not corroded. Inspect the power supply and ensure it meets the 12-24V AC/DC requirements. Update firmware if available to enhance functionality. Test transmitter range periodically to ensure reliable communication. Replace batteries in transmitters as needed. Inspect relay outputs for wear and tear. Schedule professional servicing if issues persist. Keep the manual handy for troubleshooting guidance. Regular checks prevent unexpected malfunctions and ensure long-term reliability. Proper care extends the lifespan of the AP-5 controller.

6.2 Common Issues and Solutions

Common issues with the Linear AP-5 include power supply malfunctions, antenna misalignment, and transmitter interference. For power issues, ensure the voltage is within the 12-24V range and check for loose connections. If the antenna is misaligned, adjust its position for optimal signal strength. Interference from nearby devices can be resolved by relocating the AP-5 or using a high-gain antenna. If transmitters fail to connect, verify codes are correctly programmed and batteries are fresh. Resetting the controller or updating firmware may resolve persistent problems. Refer to the manual for detailed troubleshooting steps and solutions to restore functionality efficiently.

6.3 Resetting the AP-5 Controller

To reset the Linear AP-5 controller, press and hold the “OPEN” key followed by the “1” key to activate relay K1, or the “2” key for K2. This process resets the device to factory settings, erasing all programmed user codes and transmitter data. Ensure all settings are backed up before performing a reset. After resetting, reprogram the device according to the manual’s instructions. This step is useful for resolving persistent issues or starting fresh with new configurations. Always refer to the manual for detailed reset procedures and post-reset setup guidelines.

Compatibility and Accessories

The Linear AP-5 is compatible with MegaCode transmitters, MDKP keypads, and integrates with various access control systems. Recommended accessories enhance its functionality and performance.

7.1 Compatible Transmitters and Keypads

The Linear AP-5 is compatible with MegaCode transmitters, ensuring secure and reliable communication. It supports wireless keypads like the MDKP and MDTK models, which accept user codes ranging from 2 to 6 digits. These keypads transmit signals to the AP-5 controller, enabling access control. The system can store up to 480 MegaCode transmitters, providing flexibility for multiple users. Additionally, it supports supervised safety edge transmitters, enhancing safety features. These accessories are designed to integrate seamlessly with the AP-5, offering robust and scalable access control solutions for various applications.

7.2 Integration with Other Access Control Devices

The Linear AP-5 seamlessly integrates with a variety of access control devices, enhancing its functionality. It is compatible with door strikes, mag-locks, gates, and automatic doors, making it a versatile solution for diverse applications. The AP-5 supports MegaCode transmitters and can be paired with wireless keypads, ensuring secure and reliable access control. Its high-gain superheterodyne receiver enables strong communication with compatible devices, even at distances up to 500 feet. Additionally, the AP-5 can be powered directly from the radio output of most gate operators, simplifying installation. This integration capability allows for a robust and scalable access control system tailored to specific needs.

7.3 Recommended Accessories for Enhanced Functionality

To enhance the functionality of the Linear AP-5, several accessories are recommended. The MDKP and MDTK wireless keypads provide secure user code entry, supporting 2 to 6-digit codes. Additionally, the AM-SEK Serial to Ethernet Adapter Kit enables remote management and integration with IP-based systems. For extended range, high-gain antennas can be used to maximize the AP-5’s wireless communication. Power supplies, such as a low-voltage transformer, ensure reliable operation. These accessories expand the AP-5’s capabilities, offering a comprehensive access control solution tailored to specific installation needs, ensuring optimal performance and scalability.

Safety Considerations

Ensure proper installation and handling of electrical components safely. Follow all safety guidelines to prevent hazards and ensure reliable operation of the Linear AP-5.

8.1 Importance of Proper Installation for Safety

Proper installation of the Linear AP-5 is crucial for ensuring safety and functionality. Incorrect wiring or voltage supply can lead to electrical hazards or device malfunction. Always use the recommended 12-24 volts AC/DC power supply and ensure proper grounding. Improper installation may result in unreliable operation, compromising security and safety. Follow the manual’s guidelines for mounting and wiring to prevent such risks. Regular inspection of connections and components is also essential to maintain safe operation. Consulting a qualified technician is recommended to guarantee a safe and effective setup.

8;2 Handling Electrical Components Safely

Handling electrical components of the Linear AP-5 requires caution to prevent damage and ensure safe operation. Always disconnect the power supply before performing any installation or maintenance tasks. Avoid touching electrical components with wet hands or while standing on conductive surfaces. Use insulated tools to prevent short circuits or electrical shocks. Never force connections or bend wires, as this can cause irreversible damage. Ensure all cables and connectors are securely fastened to prevent loose connections, which may lead to system malfunctions. Follow the manufacturer’s guidelines for voltage requirements (12-24V AC/DC) and grounding procedures to maintain safety and reliability.

8.3 Emergency Procedures

In case of an emergency, ensure the Linear AP-5 system is safely managed. Disconnect power immediately if a malfunction occurs; Ground the system properly to prevent damage from lightning or surges. If the system fails, reset the controller by following the manual instructions. Contact technical support for assistance with critical issues. Keep emergency contact information handy, such as the support hotline (1-800-421-1587). Regular maintenance and proper installation are key to preventing emergencies. Always follow safety protocols to avoid accidents and ensure reliable operation of the AP-5 controller in access control systems.

Warranty and Support

The Linear AP-5 is backed by a comprehensive warranty program. For support, contact Linear Technical Services at 1-800-421-1587. An RPA is required for warranty returns.

9.1 Warranty Terms and Conditions

The Linear AP-5 is covered by a warranty provided by Linear LLC, ensuring protection against manufacturing defects. The warranty period varies depending on the product and region. To process a warranty claim, a Return Product Authorization (RPA) number must be obtained from Linear Technical Support. Contact 1-800-421-1587 for assistance. The warranty does not cover damage caused by misuse, improper installation, or external factors. All returns must be authorized in advance, and proper packaging is required to avoid additional charges. For full details, refer to the official warranty documentation provided with the product or available on the Linear website.

9.2 Contacting Technical Support

For assistance with the Linear AP-5, contact Linear Technical Support at 1-800-421-1587. Support is available to address installation, programming, or operational issues. Visit the official Linear website for additional resources, including manuals, FAQs, and troubleshooting guides. For email support, submit inquiries through the contact form on their website. When reaching out, have the product model, serial number, and a detailed description of the issue ready. The support team is equipped to provide expert assistance, ensuring optimal performance and resolving any challenges promptly.

9.4 Return Product Authorization (RPA) Process

To return a Linear AP-5 for repair or replacement, obtain a Return Product Authorization (RPA) number from Linear Technical Support. Contact them at 1-800-421-1587 or through the official website. Provide details such as the product model, serial number, and reason for return. Once approved, package the unit securely, including all original accessories. Ship to the address provided by Linear, ensuring the RPA number is visible on the exterior. Retain the tracking information for your records. Note that unauthorized returns may be refused. The RPA process ensures efficient handling and prompt resolution.

The Linear AP-5 is a versatile and efficient wireless access controller, offering reliable performance for various access control needs. Refer to the manual for optimal functionality and troubleshooting.

10.1 Summary of Key Points

The Linear AP-5 is a versatile wireless access controller designed for various applications, including door strikes, mag-locks, and gates. It operates on 12-24V AC/DC, features a high-gain superheterodyne receiver, and offers a transmission range of up to 500 feet. The device supports up to 480 MegaCode transmitters and six supervised safety edge transmitters, ensuring reliable access control. Its compact design and wireless functionality make it ideal for diverse installations. Key features include relay outputs, compatibility with keypads, and simple programming for user codes. Regular maintenance and troubleshooting are essential for optimal performance. The manual provides detailed guidance for installation, operation, and addressing common issues, ensuring efficient and secure access control solutions.

10.2 Final Thoughts on the Linear AP-5

The Linear AP-5 stands out as a reliable and versatile wireless access controller, offering a blend of advanced features and user-friendly operation. Its compact design, high-gain receiver, and extensive compatibility make it a robust solution for various access control needs. With support for up to 480 transmitters and a range of up to 500 feet, it ensures secure and efficient access management. The device’s compatibility with keypads, mag-locks, and gates further enhances its adaptability. Overall, the AP-5 is a practical choice for both residential and commercial applications, providing a balance of performance, reliability, and ease of use, making it a valuable addition to any access control system.

10.3 Encouragement to Refer to the Manual

Referencing the manual is essential for maximizing the potential of the Linear AP-5. It provides detailed guidance on installation, programming, and maintenance, ensuring optimal performance and safety. The manual offers troubleshooting tips, warranty information, and advanced features to enhance functionality. By following the manual’s instructions, users can avoid common issues and ensure their system operates securely and efficiently. Keep the manual handy for future reference to address any questions or concerns that may arise, guaranteeing the AP-5 continues to meet your access control needs effectively.